Skip to main content
Fig. 5 | Bioelectronic Medicine

Fig. 5

From: Effects of waveform shape and electrode material on KiloHertz frequency alternating current block of mammalian peripheral nerve

Fig. 5

Profile plots showing all transmembrane nodal voltages, m gate, and h gate values in the top, middle, and bottom rows respectively. All values shown are averaged over a single period of the 10 kHz stimulating waveform. The left column shows the profiles from sinusoidal waveform stimulation. The middle column shows the difference between the triangle and sinusoidal stimulation profiles (in blue) and the difference between the square and sinusoidal stimulation profiles (in red). The middle profile differences are shown with the same y-axis scale as the profiles in the left column. The right column is the same data shown in the middle column, but with a 100 times zoom on the y-axis